VTWFA-1

VTWFA-1
Part Number:VTWFA-1
Dimension:10.0*109mm
Connectors:SMA
Gain:2.5dBi
Frequency:2400~2500MHz

1. Dimension(Unit:mm)
-1

2. Electrical Characteristics
2.1  GSM Antenna
Form 1

No.

Item

Specifications

Post Environmental Tolerance

1

Frequency(MHz)

2400~2500MHz

±3 MHz

2

V.S.W.R(in BW)

≤1.6︰1

3

Gain(Zenith)

2.5 dB

±0.5 dB

4

Polarization

Vertical

5

Impedance

50 Ω

2.2  Mechanical

                       Form 2

No.

Item

Specification

1

Cable

2

Connector

SMA

3

Plastic Housing

Black

4

Size

Φ10.0×109mm

 3. Reliability
Condition:Temperature: 40±5℃
Load: DC=5V±0.5 V
Quantity: 2000pcs
Sustained Time: 480h

4. Environmental Specifications
Condition:Post Environmental Tolerance (Refer to the form 1)
Temperature Range 25±3℃
Relative Humidity Range 55~75%RH
Operating Temperature Range -40℃~+85℃
Storage Temperature Range -40℃~+100℃
4.1  Moisture Proof
The device should satisfy the electrical characteristics specified in form 1 after exposed to the temperature 40±2℃ and the relative humidity 90~95% RH for 96 hours and 1~2 hours recovery time under normal condition.
4.2  Vibration Resist
The device should satisfy the electrical characteristics specified in form 1 after applied to the vibration of 10 to 55Hz with amplitude of 1.5mm for 2 hours each in X, Y and Z directions.
4.3  Drop Shock
The device should satisfy the electrical characteristics specified in form 1 after dropping onto the hard wooden board from the height of 30cm for 3 times each facet of the 3 dimensions of the device.
4.4 High Temperature Endurance
The device should satisfy the electrical characteristics specified in form 1 after exposed to temperature 80±5℃ for 24±2 hours and 1~2 hours recovery time under normal temperature.
4.5 Low Temperature Endurance
The device should also satisfy the electrical characteristics specified in form 1 after exposed to the temperature -40℃±5℃ for 24±2 hours and to 2 hours recovery time under normal temperature.
4.6 Temperature Cycle Test
The device should also satisfy the electrical characteristics specified in form 1 after exposed to the low temperature -25℃ and high temperature +85℃ for 30±2 min each by 5 cycles and 1 to 2 hours recovery time under normal temperature.