VTGPSIP-5

VTGPSIP-5
Part Number:VTGPSIP-5
Dimension:20*18*7.5mm
Mounting way: Internal
LNA Gain:N/A
Input Voltage:N/A
Cables:RF1.13 or others
Connectors: IPEX or others
Gain:0 dB
Center Frequency:1575.42 MHz

1. Dimension(Unit:mm)

 图

2. Electrical Characteristics

2.1 Dielectric Antenna

Form 1

No. Item Specifications Post Environmental Tolerance
1 Center FrequencyMHz 1575.42 MHz ±3 MHz
2 Band WidthMHz ±5 MHz ±1 MHz
3 V.S.W.Rin BW  1.51
4 GainZenith 0 dB ±0.5 dB
5 Polarization RHCP
6 Impedance 50 Ω

2.2 Mechanical

Form 2

No. Item Specification
1 Cable RF1.13 or others
2 Connector IPEX or others
3 Mounting Internal

3 Reliability

ConditionTemperature: 40±5℃ 

Load: DC=5V±0.5 V 

Quantity: 2000pcs 

Sustained Time: 480h 

4 Environmental Specifications

Condition

Post Environmental Tolerance (Refer to the form 1~2) 

Temperature range 25±3℃

Relative Humidity range 55~75%RH

Operating Temperature range -40℃~+85℃ 

Storage Temperature range -40℃~+100℃ 

4.1 Moisture Proof 

The device should satisfy the electrical characteristics specified in form 1~2 after exposed to the temperature 40±2℃and the relative humidity 90~95% RH for 96 hours and 1~2 hours recovery time under normal condition. 

4.2 Vibration Resist 

The device should satisfy the electrical characteristics specified in form 1~2 after applied to the vibration of 10 to 55Hz with amplitude of 1.5mm for 2 hours each in X , Y and Z directions. 

4.3 Drop Shock 

The device should satisfy the electrical characteristics specified in form 1~2 after dropping onto the hard wooden board from the height of 30cm for 3 times each facet of the 3 dimensions of the device. 

4.4 High Temperature Endurance 

The device should satisfy the electrical characteristics specified in form 1~2 after exposed to temperature 80±5℃for 24±2 hours and 1~2 hours recovery time under normal temperature. 

4.5 Low Temperature Endurance 

The device should also satisfy the electrical characteristics specified in form 1~2 after exposed to the temperature -40℃±5℃for 24±2 hours and to 2 hours recovery time under normal temperature. 

4.6 Temperature Cycle Test 

The device should also satisfy the electrical characteristics specified in form 1~2 after exposed to the low temperature -25℃ and high temperature +85℃ for 30±2 min each by 5 cycles and 1 to 2 hours recovery time under normal temperature.