VTGPSIP-11

VTGPSIP-11
Part Number:VTGPSIP-11
Dimension:27*27*8.7mm
Mounting way:Internal
LNA Gain:N/A
Input Voltage:N/A
Cables:RF1.13/RG178/RG174 or others
Connectors:IPEX/MMCX or others
Gain:0 dB
Center Frequency:1575.42 MHz
1.   Dimension(Unit:mm)
                             
2.   Electrical Characteristics
2.1 Dielectric Antenna
Form 1
No.
Item
Specifications
Post Environmental Tolerance
1
Center Frequency(MHz)
1575.42 MHz
±3 MHz
2
Band Width(MHz)
±5 MHz
±1 MHz
3
V.S.W.R(in BW)
1.5︰1
4
Gain(Zenith)
0 dB
±0.5 dB
5
Polarization
RHCP
6
Impedance
50 Ω
2.2 Mechanical
Form 2
No.
Item
Specification
1
Cable
RF1.13/RG178/RG174 or others
2
Connector
IPEX/MMCX or others
3
Mounting
Internal
 3.   Reliability
      Condition:Temperature: 40±5℃
                            Load: DC=5V±0.5 V
                            Quantity: 2000pcs
                            Sustained Time: 480h
 
4.   Environmental Specifications
      Post Environmental Tolerance (Refer to the form 1~2 )
      Condition:Temperature Range 25±3℃
                            Relative Humidity Range 55~75%RH
                            Operating Temperature Range -40℃~+85℃
                            Storage Temperature Range -40℃~+100℃
4.1 Moisture Proof
The device should satisfy the electrical characteristics specified in form 1~2 after exposed to the temperature 40±2℃ and the relative humidity 90~95% RH for 96 hours and 1~2 hours recovery time under normal condition.
4.2 Vibration Resist
The device should satisfy the electrical characteristics specified in form 1~2 after applied to the vibration of 10 to 55Hz with amplitude of 1.5mm for 2 hours each in X, Y and Z directions.
4.3 Drop Shock
The device should satisfy the electrical characteristics specified in form 1~2 after dropping onto the hard wooden board from the height of 30cm for 3 times each facet of the 3 dimensions of the device.
4.4 High Temperature Endurance
The device should satisfy the electrical characteristics specified in form 1~2 after exposed to temperature 80±5℃ for 24±2 hours and 1~2 hours recovery time under normal temperature.
4.5 Low Temperature Endurance
The device should also satisfy the electrical characteristics specified in form 1~2 after exposed to the temperature -40℃±5℃ for 24±2 hours and to 2 hours recovery time under normal temperature.
4.6 Temperature Cycle Test
The device should also satisfy the electrical characteristics specified in form 1~2 after exposed to the low temperature -25℃ and high temperature +85℃ for 30±2 min each by 5 cycles and 1 to 2 hours recovery time under normal temperature.