1 Dimension(Unit:mm)
2 Electrical Characteristics
2.1 LNA / Filter
Form 1
No. |
Item |
Specifications |
Post Environmental Tolerance |
1 |
LNA Gain |
28dB |
3 dB |
2 |
Noise Figure |
1.5dB |
— |
3 |
Filter Out Band Attenuation |
14dB Min f0+50MHz |
±1.0 dB |
4 |
DC Voltage |
2.7~5V |
|
5 |
DC Current |
6~12mA |
2.2 Mechanical
Form 2
No. |
Item |
Specification |
1 |
Cable |
RG174 3m / 5m or others |
2 |
Connector |
SMA / SMB / MCX or others |
3 |
Plastic Housing |
Black |
4 |
Mounting |
Magnetic / Stick |
3 Reliability
Condition:Temperature: 40±5℃
Load: DC=5V±0.5 V
Quantity: 2000pcs
Sustained Time: 480h
4 Environmental Specifications
Condition:Post Environmental Tolerance (Refer to the form 1)
Temperature Range 25±3℃
Relative Humidity Range 55~75%RH
Operating Temperature Range -40℃~+85℃
Storage Temperature Range -40℃~+100℃
4.1 Moisture Proof
The device should satisfy the electrical characteristics specified in form 1 after exposed to the temperature 40±2℃ and the relative humidity 90~95% RH for 96 hours and 1~2 hours recovery time under normal condition.
4.2 Vibration Resist
The device should satisfy the electrical characteristics specified in form 1 after applied to the vibration of 10 to 55Hz with amplitude of 1.5mm for 2 hours each in X, Y and Z directions.
4.3 Drop Shock
The device should satisfy the electrical characteristics specified in form 1 after dropping onto the hard wooden board from the height of 30cm for 3 times each facet of the 3 dimensions of the device.
4.4 High Temperature Endurance
The device should satisfy the electrical characteristics specified in form 1 after exposed to temperature 80±5℃ for 24±2 hours and 1~2 hours recovery time under normal temperature.
4.5 Low Temperature Endurance
The device should also satisfy the electrical characteristics specified in form 1 after exposed to the temperature -40℃±5℃ for 24±2 hours and to 2 hours recovery time under normal temperature.
4.6 Temperature Cycle Test
The device should also satisfy the electrical characteristics specified in form 1 after exposed to the low temperature -25℃ and high temperature +85℃ for 30±2 min each by 5 cycles and 1 to 2 hours recovery time under normal temperature.
5 Weatherproof
Put the antennas in 1m deep water for 12h, and find 100% waterproof.