VTGSMA-1

VTGSMA-1
Part Number:VTGSMA-1
Dimension:80*15mm
Mounting way:Screw / Magnetic / Stick
Cables:RG 174 3m / 5m or others
Connectors:SMA / SMB / MCX or others
Gain:2dB
Frequency:880 MHz~960 MHz / 1710 MHz~1990 MHz

1. Dimension(Unit:mm)
    

2. Electrical Characteristics
2.1  GSM Antenna

Form 1

No.

Item

Specifications

Post Environmental Tolerance

1

Center Frequency

880 MHz~960 MHz / 1710 MHz~1990 MHz

±3 MHz

2

V.S.W.R

2.0︰1

3

Gain(Zenith)

2dB±1dB@900MHz or 1dB±1dB@1800MHz

±0.5dB

4

Impedance

50Ω

±2 Ω

2.2  Mechanical
                                                                 Form 2

No.

Item

Specification

1

Cable

RG 174  3m / 5m or others

2

Connector

SMA / SMB / MCX or others

3

Plastic Housing

Black or White

4

Mounting

Screw / Magnetic / Stick

3. Reliability
       Condition:Temperature: 40±5℃
           Load: DC=5V±0.5 V
           Quantity: 2000pcs
           Sustained Time: 480h
4. Environmental Specifications
       Condition:Post Environmental Tolerance (Refer to the form 1)
              Temperature Range 25±3℃
              Relative Humidity Range 55~75%RH
              Operating Temperature Range -40℃~+85℃
              Storage Temperature Range -40℃~+100℃
4.1  Moisture Proof
  The device should satisfy the electrical characteristics specified in form 1 after exposed to the temperature 40±2℃ and the relative humidity 90~95% RH for 96 hours and 1~2 hours recovery time under normal condition.
4.2  Vibration Resist
  The device should satisfy the electrical characteristics specified in form 1 after applied to the vibration of 10 to 55Hz with amplitude of 1.5mm for 2 hours each in X, Y and Z directions.
4.3  Drop Shock
  The device should satisfy the electrical characteristics specified in form 1 after dropping onto the hard wooden board from the height of 30cm for 3 times each facet of the 3 dimensions of the device.
4.4  High Temperature Endurance
  The device should satisfy the electrical characteristics specified in form 1 after exposed to temperature 80±5℃ for 24±2 hours and 1~2 hours recovery time under normal temperature.
4.5  Low Temperature Endurance
  The device should also satisfy the electrical characteristics specified in form 1 after exposed to the temperature -40℃±5℃ for 24±2 hours and to 2 hours recovery time under normal temperature.
4.6  Temperature Cycle Test
  The device should also satisfy the electrical characteristics specified in form 1 after exposed to the low temperature -25℃ and high temperature +85℃ for 30±2 min each by 5 cycles and 1 to 2 hours recovery time under normal temperature.